What happened
The defective exhaust was replaced with a new one on 15 February 2017. The replacement followed numerous problems and repeated breakdowns since early December 2016, despite a few interim repairs to the exhaust.The maintenance work was carried out on the afternoon of Wednesday 15 February by volunteers from the flying club. I was present at the end of the work and asked for a ground run to be carried out before the cowling was refitted. This run was carried out by the person in charge of maintenance, and as no anomaly was found, the cowling was refitted.
I flew for 18 minutes that same evening on an instructional flight, just before official night, and everything seemed to be working.
First thing the next morning, Thursday 16 February, I flew again with another student: the weather was not very good and we carried out a full pre-flight inspection while waiting for the cloud base to lift. Nothing to report. We then made a 20-minute flight at low height, and still nothing to report.
The same day, a student of another instructor also made a dual flight and a solo flight. Before his flight, I saw him carry out a full inspection with the cowling removed.
The following day, Friday 17 February, I made a training flight with a student; she asked me whether she should remove the cowling and I told her no (the cowling had been removed on the Nynja by a student before the previous flight and I had watched him do it). So we set off after a pre-flight inspection without removing the cowling.
On the crosswind leg after take-off, my student told me that she found a smell suspicious and was worried by it; I asked her what she decided to do. She told me: 'I'll land.' I told her that in my opinion it was the smell of grease from the refitting of the exhaust; at that point I was not bothered by the smell. Moreover, I had also refused to fly with her on the morning of 15 February because of a smell of exhaust fumes, and she had then cancelled her flight. She had informed a volunteer in charge of repairs, who had replied that she had been right not to fly but that it was certainly not dangerous. Did that remark encourage me to continue the flight? I did not want to put the volunteers who had carried out the repairs in an awkward position.
We made a few steep turns, and my student again pointed out that the smell was bothering her more and more; we then carried out a forced landing practice (PTS) with the engine off. This PTS was flown a little too close to the runway and I decided to repeat the exercise. During the climb, I was bothered by the smell, which was starting to give me a headache, and my student told me that she was beginning to feel unwell; we had reached 2000ft. We then shut down the engine for a PTS and landed.
During the descent, I wanted to open the door because I too was starting to have difficulty breathing.
After landing, we removed the cowling and inspected the exhaust outlets. We found:
- rear right outlet completely loose,
- rear left outlet not loose but showing traces of smoke.
My student informed the people in charge of maintenance.
.
Pilot's comments
In the afternoon, I made another instructional flight in a weight-shift microlight and found that I was very nauseous and unable to think clearly. I therefore asked my student to land immediately and, as he was at the end of his training and the conditions were gentle, I sent him off solo to fly over Saint-Omer. Meanwhile, I checked on my student from the morning, who was feeling the same symptoms. After a discussion with the vice-president and the head of training at the flying club, I decided to follow the vice-president's advice and go to the emergency department.The doctor found mild poisoning, with low oxygen saturation and no after-effects (ECG and blood tests normal). I was able to leave the emergency department at the end of the afternoon and reassure everyone.
Lessons learned:
My errors
1 - I did not carry out a full pre-flight inspection with the cowling removed, though I am not sure I would have spotted the loose fastening.
2 - Convinced that it was a smell of grease, I continued the flight instead of landing after take-off.
Improvements to be made:
1 - Installing a carbon monoxide detector in the Nynja. I personally asked for this several times, but on the grounds that the Nynja is not airtight, no detector card has been installed.
2 - A visual mark on the nuts would make it possible to carry out a real check during the pre-flight inspection. Without a mark, I am not sure I would notice that a nut is working loose or has come loose.
3 - The exhaust was completely replaced, but not the self-locking nuts securing it.
4 - A checklist for the pre-flight inspection would be a plus.