What happened
While returning from a navigation flight, I had an electrical failure in flight. The voltmeter showed a voltage drop to 8 V, signalling a serious problem, given my fuel-injected engine's dependence on electricity. While trying to solve the problem, I found that the "Reg" circuit breaker, which protects the regulator, kept tripping, indicating a more serious failure.
At about 2200 feet of altitude, I decided to turn back towards Vienne aerodrome, 4 nautical miles away. During the journey, I lost the use of my transponder and my radio. Faced with the imminent loss of engine power, I considered an emergency landing in a nearby field but finally chose to try to reach Vienne.
Shortly afterwards, the engine stopped. With no electronic equipment, I had to make an emergency landing, aiming for the 19 threshold at Vienne. I adjusted my path to avoid another microlight on the runway and landed outside the runway markers.
Immediately afterwards, I contacted Lyon by phone to report my situation. The emergency services had been alerted but the incident was closed following my call.
Pilot's comments
Flying regularly on my own machine, training regularly, and having a machine suited to off-airfield landings and equipped with a parachute / distress beacon / transponder (contact with SIV) put more chances on your side in the event of a failure.
The emergency confirmed my ability to stay calm and think clearly, even under intense pressure, which is hard to assess in exercises with instructors. It was essential to fly towards the nearest runway before trying to solve the problem, which let me reach an aerodrome in a glide, something that would not have been possible with a few seconds less.
On the technical side, I realised the problem could have been detected more than 30 minutes before the failure if I had been alerted more effectively to the charging problem (failed alternator), so I modified my system to include a digital voltmeter / ammeter with visual alerts in case of a problem. I also added a backup battery giving more than an hour of endurance in case of a similar problem in future.
Federation analysis
With an injection system fitted to a 9-series Rotax, it is safer to have redundancy in case of loss of electrical power. A backup battery with a warning light that effectively tells you about the fault in question. This should be an integral part of the reasoning when installing an injection system, given the electrical consumption of the high-pressure electric pump.