Skip to content
French Microlight Federation My Space
Home
Flying Entry to the Flying section

Fly

What is microlighting?Where to fly?Licence and insuranceMedicalHandivolMechanics

Become a pilot

The pilot certificateMicrolight examTrainingTrial flight

Regulations

Regulatory documentsAirspacePlan your flightsAirfieldsOPS ULM — order of 17/02/25

Federation support

Youth supportThe BIAGrantsIn-Flight Companion training
Instruction Entry to the Instruction section

Network

Clubs and schoolsInstructors

Instructors

Microlight instructor trainingList of instructors by départementKnowledge refresherThe teaching programmeTeaching and technical sheets

subvention aux instructeurs

✦ Aide jeune – Accès à la qualification instructeur (nouvelle page)
Sport
Safety Entry to the Safety section

Prevention

DirectivesParachutesFederation prevention

Safety reports

REX — submit and browseFlight Safety BulletinReturn to Flying (REV)ECCAIRSCSV flight safety officersList of REX reports

Alerts

Safety news

Files and quizzes

Good practice
News Entry to the News section

Read

Federation newsULM Info — the magazineClub and school life

Calendar

EventsSubmit an eventFederation events

Media

Photos & VideosDocuments to downloadPractical guides

Stay informed

Frequently asked questions
The Federation Entry to the Federation section

The institution

Les ÉlusLes pôlesLes comités régionauxLa DTNÉthique et déontologieProtection des populations de l’ULMULM & EnvironnementLa Fédération en chiffresTextes officielsAssemblée Générale

Federation events

The Youth Microlight Tour (Tour ULM Jeunes)Microlight World ChampionshipsFesti'ULM

Join us

RecruitmentContactReport
Site map

SafetySafety report

Onboard system failure disrupting flight management

During a navigation flight back to our microlight airfield, we suffered an electrical failure. It was a weight-shift microlight with two people on board; the nature of the failure has not yet been checked because it was sudden and not persistent.

REX no. 8263
Year
2024
Seaplane
No
Weather
Favourable
Damage
No
Aircraft
Weight-shift microlight
Date of flight
15/09/2024
Crew
Flight with a passenger
Role on board
Pilot
Event type
Onboard system failure disrupting flight management
REX category
Technical
Phase of flight
in the cruise
Type of flight
a trip - a navigation
Equipment
Parachute, Radio, Tablet
Possible consequences
Off-field landing
Environment
over flat terrain

What happened

During a navigation flight back to our microlight airfield, we suffered an electrical failure.

It was a weight-shift microlight with two people on board; the nature of the failure has not yet been checked because it was sudden and not persistent.

The aircraft lost 100% of its electrical supply for about 1 second, then the power came back.

Several restart attempts were made, including switching the fuel pump. Afterwards it turned out that the aircraft does not allow a restart if the cruise throttle has not returned to the fully idle position, which was the cause preventing us from restarting in flight.

In parallel with the restart attempts, we began an approach for an off-airfield landing.

The area being rather dense in inhospitable features (motorway, high-voltage line, low-voltage line, village, woods and road), the in-flight restart attempts were quickly stopped so that we could concentrate fully on landing in an uncultivated field.

Once safely on the ground, we were able to restart the machine, redo a pre-flight, run engine tests and prepare an in-flight restart protocol in case of another failure.

We then lined up on an uncultivated field that was long enough to take off and climb safely.

The rest of the return went without problems.