What happened
On a trip between Chambley and the Po delta in Italy via the Mediterranean coastline, after more than 9 hours of flying and 8 min from the final destination, the engine suddenly stopped when we were at 1000 ft AGL (in Italy you never fly very high), followed by an off-airfield landing.
A first "hot" analysis made us blame the mechanical pump (changed less than a year ago), since we were able to take off again using the electric pump.
It turned out 2 days later on the return flight, and after the informed advice of Pierre Pouchès (Peyo), that the origin of the problem was clogging of a micro-filter at the inlet of the electric pump and that its installation had no bypass.
Pilot's comments
Two pieces of advice for those whose machines have an additional electric pump:
- Check the condition of the filter at the pump inlet. On the Pierburg fitted to my machine you need a small piece of wire to remove it. Peyo recommends taking it out and never putting it back as long as there is a filter upstream in the circuit.
- Check that there is a bypass with a non-return valve around the electric pump.