What happened
With a student, we are back at LFLG (controlled airfield) after a local instruction flight. We are on downwind, number 3 to land. A high oil pressure alarm suddenly appears on the EMS. After acknowledging the alarm, the oil pressure indicator shows a pressure of 11 bar, above the upper limit of the Rotax 912 ULS, which is 7 bar. The other engine parameters are nominal. Unsure of the real situation, I take the controls, make a Mayday call on the radio, obtain priority to land and carry out a PTU (forced landing pattern). The number 1 traffic on short final goes around, and number 2 flies a 360 hold. Once on the ground, the oil pressure returns to normal, but rises again while taxiing to the parking area. The microlight is grounded for examination by our workshop.
Pilot's comments
I monitored the oil temperature, because a real pressure problem generally leads to a rise in temperature. In our case the temperature was not changing, which made me lean towards a sensor failure rather than a "real" engine failure. The high oil pressure alarm appeared while we were well positioned for a PTU, so that choice was natural. If the event had occurred earlier in the flight, outside the aerodrome area, I think I would have headed for the aerodrome, limiting power and staying high, while monitoring the oil temperature and ready to suffer an engine stoppage at any moment. Once within gliding range of the aerodrome, I would have carried out a high-key/low-key pattern or a PTU.